CRITERIA TO MEASURE THE QUALITY OF TVAR ESTIMATION FOR AUDIO SIGNALS - Université Paris Cité Accéder directement au contenu
Communication Dans Un Congrès Année : 2007

CRITERIA TO MEASURE THE QUALITY OF TVAR ESTIMATION FOR AUDIO SIGNALS

Résumé

An audio signal can be represented by a Time-Varying Auto- Regressive (TVAR) model, whose parameters can be estimated by a particle filter. Since the original parameters are unavailable for real signals, an evaluation of the estimation may be traditionally performed through indirect criteria such as the SNR of the signal denoised by a Kalman filter based on the TVAR estimated model or through a statistical analysis based on the observation. We propose a new evaluation method based on the statistical characterization of the output of the inverse TVAR estimated model. The proposed criteria are much more suitable and coherent when correlated to the direct criterion (cepstral distance), which is related to the estimated TVAR parameters.
Fichier principal
Vignette du fichier
eusipco07.pdf (1.45 Mo) Télécharger le fichier
eusipco_imen.pdf (1.7 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Format : Autre
Loading...

Dates et versions

hal-00686317 , version 1 (09-04-2012)

Identifiants

  • HAL Id : hal-00686317 , version 1

Citer

Imen Samaali, Gaël Mahé, Monia Turki-Hadj Alouane. CRITERIA TO MEASURE THE QUALITY OF TVAR ESTIMATION FOR AUDIO SIGNALS. European Signal Processing Conference, Feb 2007, poznan, Poland. ⟨hal-00686317⟩
40 Consultations
169 Téléchargements

Partager

Gmail Facebook X LinkedIn More